Olympus Epoch 650 Ultrasonic Flaw Detector

$6,499.00

The Epoch 650 has quickly become the industry standard for portable, easy to use rugged flaw detectors.

1 in stock

SKU: 180126A Categories: ,

Description

Olympus Epoch 650 Ultrasonic Flaw Detector
Stock #180126A
The Epoch 650 has quickly become the industry standard for portable, easy to use rugged flaw detectors. This unit has very little use, and has only been used inside a classroom for NDI instruction. The Epoch 650 comes with the new "perfectsquare" square wave tunable pulser, along with having a high output VGA screen easily readable even in direct sunlight. Weight is down to a little over a 3lbs, and including the shoulder strap, is the perfect unit for inspections in hard to reach places. Don't Miss this opportunity to get a like new flaw detector for a fraction of its Retail Price!
Included with Sale
-Olympus Epoch 600
-Case
-Charger
-Power Cable
 
Specifications:

The large, full VGA transflective display combined with our patented digital high dynamic range receiver provides a stable, striking A-scan representation in any lighting condition. The EPOCH 650 is designed to meet the requirements of EN12668‑1 and allows a full range of standard and optional flaw detection features. Multiple onboard reporting tools and a comprehensive data filing system enable you to easily collect and report high quality inspection data. The rugged, ergonomic design allows use in nearly any inspection environment, while the flexible PerfectSquare™ pulser and highest number of digital filters in its class can tackle nearly any application.

The EPOCH 650 Digital Ultrasonic Flaw Detector combines Olympus’ industry leading conventional flaw detection capabilities with the efficiency of a highly portable, intuitive instrument. The EPOCH 650 flaw detector’s blend of efficient menus and direct access keys allows you to take advantage of the highest quality flaw detection platform with exceptional ease of use.

Designed for All Inspection Environments

The EPOCH 650 is designed for use in nearly any inspection environment, from bench top testing in a laboratory to extreme outdoor and hazardous conditions. Designed for IP rating in either knob (IP66) or navigation pad (IP67) configurations, and tested to very high environmental and reliability standards, the EPOCH 650 allows users in any inspection environment to feel confident in both the performance and durability of the instrument.

Key Features

  • Designed to meet the requirements of EN12668-1
  • PerfectSquareTM tunable square wave pulser
  • Full screen A-scan mode
  • Digital high dynamic range receiver
  • Thirty digital filters for enhanced signal-to-noise ratio
  • 2 kHz PRF for rapid scanning
  • Knob or navigation pad adjustment configurations
  • Large, full VGA sunlight readable display
  • 15+ hours of battery life
  • Standard dynamic DAC/TCG and onboard DGS/AVG
  • Multiple on-board report formats
  • MicroSD memory card for data transfers
  • Optional Corrosion Module software with Encoded B-scan
  • USB On-The-Go (OTG) for PC communication
  • Alarm and VGA outputs
  • Optional analog output

Simple and Comfortable Operation

The EPOCH 650 design is focused on providing a very high level of flaw detection with the simplicity of a basic instrument. The EPOCH 650 is designed to be ergonomic, intuitive, and practical for both experienced and novice ultrasonic inspectors.

Intuitive User Interface

The EPOCH 650 user interface is based on the industry leading EPOCH 600 flaw detector. The EPOCH 650 combines a simple menu structure for instrument settings, calibration and software feature adjustment, with the EPOCH brand’s hallmark direct-access key approach

for critical inspection functions such as gain and gate adjustment, screen freeze, and file save. Supported in multiple languages, the EPOCH 650 user interface is intuitive for any level of operator.

Epoch 650 Standard Screen Mode

EPOCH 650 DGS/AVG feature - Standard Screen mode

Vibrant VGA Display with Full Screen Mode

The EPOCH 650 features a full VGA (640 x 480 pixels) resolution display. The horizontal design of the EPOCH 650 optimizes the A-scan size and readability on this high quality display. Built with transflective technology, this VGA display provides excellent clarity in indoor, low lighting conditions using its powerful backlight, as well as in direct sunlight by using the ambient light as a pseudo-backlight.

The full screen mode feature enhances this vibrant display to provide the largest A-scan in an EPOCH series flaw detector!

EPOCH 650 Full Screen Mode

EPOCH 650 DGS/AVG feature - Full Screen mode

Instrument Inputs/Outputs USB Ports USB On-The-Go (OTG)
RS-232 Port Yes
Video Output VGA output standard
Analog Output 1 analog output (optional), Selectable 1 V/10 V Full Scale, 4mA max
Alarm Output 3 alarm outputs, 5 V TTL, 10 mA
Trigger I/O Trigger input, 5V TTL;
Trigger output, 5V TTL, 10 mA max
Encoder Inputs 1-axis encoder line (quadrature - Corrosion Module mode only)
Environmental Ratings IP Rating Designed to meet the standards of the Ingress Protection (IP) rating number IP67 (navigation pad version) or IP66 (knob version) per IEC 60529-2004 (Degrees of Protection provided by enclosures – IP Code).

The product design was confirmed to meet the IP rating by means of Olympus internal design verification test process that occurs prior to the release of the product to production.

Explosive Atmosphere Safe operation as defined by Class I, Division 2, Group D, as defined in the National Fire Protection Association Code (NFPA 70), Article 500, and tested using MIL-STD-810F, Method 511.4, Procedure I.
Shock Tested MIL-STD-810F, Method 516.5 Procedure I, 6 cycles each axis, 15g, 11 ms half sine.
Vibration Tested MIL-STD-810F, Method 514.5, Procedure I, Annex C, Figure 6, general exposure: 1 hour each axis
Operating Temperature –10 °C to 50 °C (14 °F to 122 °F)
Battery Storage Temperature 0 °C to 50 °C (32 °F to 122 °F)
General Overall dimensions (W x H x D) 236 mm x 167 mm x 70 mm (9.3 in. x 6.57 in. x 2.76 in.)
Weight 1.6 kg (3.5 lb), including lithium-ion battery
Keypad English, International, Japanese, Chinese
Languages English, Spanish, French, German, Japanese, Chinese, Portuguese, Russian
Transducer connections BNC or Number 1 LEMO
Data storage 100,000 IDs onboard, removable 2 GB MicroSD card (standard)
Battery type Single lithium-ion rechargeable standard
Battery life 15 h to 16 h (lithium-ion)
Power requirements AC Mains: 100 VAC to 120 VAC, 200 VAC to 240 VAC, 50 HZ to 60 Hz
Display type Full VGA (640 x 480 pixels) transflective color LCD, 60 Hz update rate
Display dimensions (W x H, Diag.) 117 mm x 89 mm, 146 mm (4.62 in. x 3.49 in., 5.76 in.)
Pulser Pulser Tunable Square Wave
PRF 10 Hz to 2000 Hz in 10 Hz increments
Energy settings 100 V, 200 V, 300 V or 400 V
Pulse width Adjustable from 25 ns to 5,000 ns (0.1 MHz) with PerfectSquare™ technology
Damping 50, 100, 200, 400 Ω
Receiver Gain 0 to 110 dB
Maximum input signal 20 V p-p
Receiver input impedance 400 Ω ± 5%
Receiver bandwidth 0.2 MHz to 26.5 MHz at -3 dB
Digital filter settings Thirty digital filter sets standard
Seven EN12668-1:2010 compliant filters (0.2-10 MHz, 2.0-21.5 MHz, 8.0-26.5 MHz, 0.5-4 MHz, 0.2-1.2 MHz, 1.5-8.5 MHz, 5-15 MHz)
Rectification Full-wave, Positive Half-wave, Negative Half-wave, RF
System linearity Horizontal: ± 0.5% FSW
Resolution 0.25% FSH, amplifier accuracy ± 1dB
Reject 0 to 80% FSH with Visual Warning
Amplitude measurement 0 to 110% full screen height with 0.25% resolution
Measurement rate Equivalent to PRF in all modes
Calibration Automated calibration Velocity, Zero Offset
Straight Beam (First Backwall or Echo-to-Echo)
Angle Beam (Soundpath or Depth)
Test modes Pulse Echo, Dual, or Through Transmission
Units Millimeters, inches, or microseconds
Range 3.36 mm to 13,388 mm (0.132 in. to 527.10 in.) @ 5,900 m/s (0.2320 in./μ)
Velocity 635 m/s to 15240 m/s (0.0250 in./µs to 0.6000 in./µs)
Zero offset 0 µs to 750 µs
Display delay -59 mm to 13,401 mm (-2.320 in. to 526.97 in.) @ longitudinal velocity in steel
Refracted angle 0° to 90° in 0.1° increments
Gates Measurement gates 2 fully independent gates for amplitude and TOF measurements
Gate start Variable over entire displayed range
Gate width Variable from Gate Start to end of displayed range
Gate height Variable from 2 to 95% full screen height
Alarms Positive and Negative Threshold, Minimum Depth (Gate 1 and Gate 2)
Measurements Measurement display locations 5 locations available (manual or auto selection)
Gate (1, 2) Thickness, Soundpath, Projection, Depth, Amplitude, Time-Of-Flight, Min./Max. Depth, Min./Max. Amplitude
Echo-to-Echo Standard Gate 2-Gate 1, Optional IF Gate Tracking
Other measurements Overshoot (dB) value for DGS/AVG, ERS (equivalent reflector size) for DGS/AVG, AWS D1.1/D1.5 A, B, C and D values, Reject Value, Echo to RefdB values
DAC/TCG Standard
DAC points Up to 50 points, 110 dB dynamic range
Special DAC modes Custom DAC (up to 6 curves), 20-80% View
Curved surface correction Standard OD or Bar correction for Angle Beam measurements
Corrosion (optional) Zero-cross measurement algorithm, V-Path correction, Single or Echo-to-Echo, Encoded B-scan

 

 

 

Trade Ins: We offer some of the highest prices on your used test equipment. We do partial trade ins or will buy your used equipment outright. An estimated trade in value will be assessed within 24 hours of receiving a value request.
Payment terms: We accept payment prior to shipping by Visa, MasterCard, AMEX, and Paypal (up to $10.000).  Businesses and Universities, please call for payment options.  Please notify us of method of payment in a timely fashion after the auction has ended. If a buyer has not made any attempt to contact us 7 days after this auction's end time we will assume they are forfeiting the auction and the item will no longer be available to them.
International Buyers: We reserve the right to accept or decline international Paypal and credit cards. International shipping is available, but clearing customs will often result in delivery delays.
Shipping Terms:  Buyer pays for shipping and packaging for this item. International buyers will pay for shipping charges to their country.  
 
* Shipping and handling fees are not refundable under any circumstances. In the case of a return, the buyer is responsible for all shipping fees.
* Shipping for international buyers will be invoiced separately from the purchased product due to the high expense of shipping charges.
* Your phone number is required for shipping purposes, so please provide it with all correspondence.
* Please note that calculated shipping is based on UPS.  We also reserve the right to ship for the same cost via FedEx or other carriers.
Packaging: All items will be packaged with materials necessary to ensure that the equipment will be adequately protected from the shipping process.
Feedback:  We appreciate Positive feedback. We leave feedback as soon as we get feedback from you. If you have any problems with the sale, please try to resolve it with us before you leave us a Neutral or Negative feedback.

Warranty: No warranty is expressed or implied with any unit. All sales include a 3 day right of return (ROR).  For any reason, within 72 hours of taking possession of the item, the buyer can return the item for a complete refund minus all shipping costs.

Return Policy:  You can return the item for any reason within three days. We put great effort into thoroughly documenting each piece of equipment, typically with very detailed pictures and video clips.  We strongly encourage you to study these images closely before you commit to purchasing the item. Please call or email us if you have any questions about anything that you are uncertain about. It is critical that you confirm that this item suites your needs within the three day return policy period. Any returns after two weeks will not be entertained, and we will automatically escalate to Ebay. If you choose to open an Ebay return case, and we are forced to accept the return, you are responsible for the following:
*Return Shipping and insurance of the item to our Store at the following address:
GP-Technical
246 Pooler Parkway Suite E
Pooler, GA 31322
*A Restocking fee of 10% of the purchase price for every week (after the initial 3 day return period) that the item is in your possession, not to exceed two weeks.
 

 

Reviews

There are no reviews yet.

Be the first to review “Olympus Epoch 650 Ultrasonic Flaw Detector”

Your email address will not be published. Required fields are marked *

12 + nineteen =